PRODUCTS
Anti-static cement mortar – wear-resistant, non-sparking, conductive mortar
Main business:Building, infrastructure, industrial, mining, marine engineering, military engineering, expressway, tunnel, bridge, concrete repair, installation of large-scale mechanical equipment, wind power equipment, foundation bolt fixing, etc. High-performance, early-strength, micro-expansion, self-compacting, large-flow leveling, rapid repair cement grouting material
- Commodity name: Anti-static cement mortar – wear-resistant, non-sparking, conductive mortar
- Description
-
1. Packaging and Logistics Delivery Date Guarantee
Packaging Three-ply film-composite bag Specifications 25KG/ bag Volume 60*40*15 cm³ Minimum order quantity 1000KG Minimum order quantity Delivery date 1-7 Workday Shelf life Dry and well-ventilated 180 days Transaction method FOB/EXW Payment method Telegraphic Transfer / Letter of Credit Ship goods FOB Shanghai / Ningbo 2. Product Description
Anti-static cement mortar is a specialized functional mortar designed for flooring applications that require conductive (anti-static) properties. By adding conductive materials—such as conductive powders or conductive fibers—to conventional cement mortar, a uniform conductive network is formed. This network enables the rapid and efficient dissipation of static charges, preventing the accumulation of static electricity that could lead to sparks or interference. As a result, it provides safe protection for sensitive electronic equipment and environments that are prone to flammability or explosion hazards.
Core working principle:
Traditional cement mortar is an insulator with a very high volume resistivity. Antistatic mortar, on the other hand, incorporates conductive components—such as graphite, carbon black, metal powders, or fibers—to create a continuous and stable conductive pathway within the mortar. When static charges accumulate on the surface, they can be quickly dissipated into the ground through these pathways, thereby eliminating static electricity.

Main features:
1. High-efficiency static conductivity: Possesses stable and low surface and volume resistivity, enabling rapid dissipation of static electricity.
2. High mechanical strength: Exhibits excellent compressive and flexural strength, is wear-resistant and durable, and has a long service life.
3. Environmentally friendly and harmless: Most products are water-based, non-toxic, odorless, and pollution-free, meeting environmental protection requirements.
4. Easy construction: It bonds firmly to concrete substrates and can be applied by scraping just like ordinary mortar, making it easy to ensure a smooth floor surface.
5. Corrosion resistance: Possesses excellent resistance to alkalis, oil stains, and other corrosive substances.
3. Technical Parameters
Technical indicators Unit Standard requirement/Typical value Test Standard/Remarks Electrostatic performance Surface resistance (Rs) Omega 1.0 × 10 4 ∼1.0×10 9 According to SJ/T 11294-2018 or customer requirements. Volume resistance (Rv) Omega 1.0 × 10 4 ∼1.0×10 9 According to SJ/T 11294-2018 Mechanical Properties Compressive strength MPa ≥ 25.0 (28 days) GB/T 17671 Flexural strength MPa ≥ 8.0 (28 days) GB/T 17671 Wear resistance % ≥ 300% (or groove length ≤ 30mm) Compared to standard cement mortar Bond strength MPa ≥ 1.5 (with concrete substrate) Ensure there is no hollowness or detachment. Shrinkage rate % ≤ 0.15% Ensure the ground doesn't crack. Workability Fluidity (as needed) mm 150-180 (optional) Self-leveling antistatic mortar Available time min ≈ 30-60 At room temperature 4. Scope of Use
Anti-static cement mortar is primarily used in any environment where it is necessary to prevent the accumulation of static electricity, ensure safety, and protect equipment and products.
(1) Electronics, Communications, and Computer Industries
● Electronic component manufacturing workshop: In workshops for manufacturing integrated circuits, chips, and semiconductors, static electricity can damage precision components.
● Communication equipment rooms: switch rooms, server rooms, data centers, and the like.
● Electronics Assembly and Testing Workshop: An area dedicated to the assembly, testing, and repair of precision electronic products.
(2). Flammable and Explosive Hazardous Areas
● Petrochemical industry: Gas stations, refineries, chemical plants, hazardous-material warehouses, etc., to prevent electrostatic sparks from causing explosions or fires.
● Aerospace: Aircraft hangars, fueling areas, ammunition storage facilities, and spacecraft assembly workshops.
● Fireworks and firecrackers production and storage warehouse.
(3) Medical, Precision Instruments, and Laboratories
● Hospital operating rooms: Prevent electrostatic interference with sensitive medical equipment (such as MRIs) and the explosion of anesthetic gases.
● Biological laboratories and pharmaceutical factories: Certain experimental environments and sterile workshops that are sensitive to static electricity.
● Precision Instrument Manufacturing and Metrology Laboratory.
(4) Other public and industrial venues that require antistatic protection
● Military command center, communications hub.
● Financial industry data center.
● Large supermarkets, logistics warehouses (high-rack warehouses).
● Textile, paper, and printing mills (to prevent static electricity from causing adhesion and operational inconvenience).
5. Precautions for Use
Construction environment temperature: -5°C to 35°C. The water-to-cement ratio is an important performance indicator for this product. Please add water according to the manufacturer’s specified water-to-cement ratio, and use mechanical mixing equipment to ensure thorough and uniform blending before construction! If the water-to-cement ratio is improperly adjusted, it may affect the product’s performance. This product is a finished item—do not add any other substances arbitrarily, as this could compromise its functionality and quality system! If this product has expired, it should be properly reconditioned before reuse. Any leftover material that is not fully used after mixing must never be mixed with fresh material for further use! When carrying out outdoor construction in rainy weather, a rain shelter must be set up. The mixed material must be used within 30 minutes; once the initial setting time has passed, the slurry will begin to set and lose its effectiveness! Once the package is opened, the contents must be used up in one go to prevent moisture absorption and clumping.
6. Construction Scenarios
7. Reasons to Choose Us
- Our company has a professional technical R&D team that provides free assistance in resolving all technical challenges you may encounter during construction.
- The raw materials used in our company’s products undergo rigorous screening, and we carefully select imported admixtures that are scientifically proportioned. The quality tolerance for the three-stage processing does not exceed one-thousandth of a percent, ensuring that their functional characteristics meet the diverse application requirements of our customers.
- High cost performance: Choose our company’s products. You’ll save 50% on labor, 50% on materials, and 50% on time—boosting construction efficiency and delivering significant economic benefits. We’ll ensure the quality of your project, putting your mind at ease and eliminating any future worries.
- Provide third-party type test reports, certificates of conformity, warranty certificates, special invoices, MSDS, and TCIR.
- Qualification Certifications: CCC, CMA, CNAS, ISO9001, CE/FCC; Product Implementation Standard: JC/T2653-2022
- We have successful track records in the supply chain for large-scale onshore and offshore wind power projects both domestically and internationally. Quality commitment guaranteed!

Factory Strength

Qualification
Message